preloader

Infrastructure and Facilities

INFRASTRUCTURE AND FACILITIES

The Department of Pathology provides comprehensive diagnostic, academic and research facilities supporting undergraduate and postgraduate education, patient care and scientific advancement.

Laboratory / Section Facilities, Equipment & Scope of Work
1. Histopathology Laboratory Specimen receiving and accessioning area, Grossing room, Tissue processing section, Paraffin embedding station, Rotary microtomes, Slide preparation and labeling, Microscopy workstations, Histopathology reporting area, Tissue archival facility, Autopsy — Medicolegal and clinical postmortem reporting.
2. Cytopathology Fine needle aspiration cytology, Fluid cytology for malignant cells, PAP smear examination, Routine body fluid examination, Sputum cytology, CSF examination and cytology.
3. Hematology Blood collection, Automated Hematology Analyzer, Hemogram, HPLC, Coagulation profile (BT/CT), Smears for malarial parasites, Peripheral smear examination, Platelet count, Reticulocyte count test and sickling test, LE (Lupus Erythematosus) cells, ESR, PT/APTT, Bone marrow aspiration.
4. Clinical Pathology Stool examination, Urine examination, Semen analysis.
5. Blood Bank / Transfusion Medicine Blood Donation Programme (Indoor and Outdoor), Blood grouping and cross-matching, Coomb's Test, Component separation, Blood storage facilities, Serological Testing, Plasmapheresis, NAAT.
ACADEMIC INFRASTRUCTURE

Undergraduate Teaching Facilities:

  • Demonstration rooms
  • Pathology museum
  • Practical laboratory
  • Histopathology slide collection
  • Gross specimen collection
  • Teaching microscopes
  • Digital teaching resources

Postgraduate Facilities:

  • PG research laboratory
  • Dedicated microscopy workstations
  • Seminar room
  • Journal club facility
  • Slide discussion area
  • Case discussion room
  • Dissertation/research facilities
  • Library
QUALITY & SAFETY INFRASTRUCTURE

The department emphasizes:

  • Standard Operating Procedures (SOPs)
  • Internal Quality Control
  • External Quality Assurance
  • Biomedical waste management
  • Infection prevention
  • Laboratory safety protocols
  • Chemical safety
  • Fire and emergency safety
  • Equipment maintenance and calibration
LIBRARY FACILITY DATA (Combined Departmental and Central Library Data)
Particulars In Department In Central Library
Number of Books 208 20,750 (Pathology – 1,383)
Total books purchased in the last three years 159 2,310 (Pathology – 159)
Total Indian Journals available 08 72 (Pathology – 10)
Total Foreign Journals available 15 151 (Pathology – 05)
PATHOLOGY MUSEUM & SPECIMEN COLLECTION

Overview: Pathology Museum has a collection of rare and interesting specimens for undergraduate and postgraduate students.

Nature of Work Done:

  • Mounting of surgical and post-mortem specimens for pathology and other departments
  • Display of specimens with description according to systems
  • Conducting undergraduate and postgraduate teaching sessions

  • Space: 140 sq. mtr.
  • Total number of Mounted Specimens: 497
  • Total number of Wet Specimens: 158
  • Total number of Charts/Diagrams: 74
  • Arrangement & Catalogues: List of charts, photographs, models displayed in a rack. 80 charts (system-wise) and 10 models. Gross and microscopic descriptions/catalogues of all specimens are available to students.
  • Seating Arrangements for Students: Level type, Total Number: 40, Ante-room: Yes.
AVAILABLE INSTRUMENTS LIST & EQUIPMENT STATUS
Sr. No. Name of Instruments / Equipment Required (UGMSR-23) Functional / Status
(A) GENERAL — Histopathology / Cytopathology / Hematology / Clinical Pathology for Students
01 LED Binocular Microscopes for Students with Scanner (10X, 40X, Oil immersion) & Battery backup 60 100
02 Stop watch reading at 1/5 second 05 05
03 Haemocytometers with red and white pipettes 90 110
04 Staining jars for slides 25 25
05 Urinometers (Mercury based instruments to be replaced) 15 15
06 Centrifuge tubes graduated 20 20
07 Graduated cylinders (100 cc to 1000 cc) 10 10
08 Pipettes of various sizes with disposal tips, Reagent bottles, Dropping bottles & Reagents 30 30
(B) Morbid Histology and Morbid Anatomy
01 Manual Rotary Microtome 02 02
02 Automated Rotary Microtome 01 01
03 Cryostat 01 01
04 Hot plate & Water bath (Tissue Floatation) 02 02
05 Paraffin embedding bath 02 02
06 Heated Paraffin Embedding Module / Cold Plate / Automated Tissue Processor 02 00
07 Autoclave & Distilled water plant / Ultrapure water solution 02 02
08 Centrifuge machine 05 06
09 Digital SLR Camera (20 MP) with accessories & Digital Automatic camera (>5 MP) 01 01
10 Coplin jars, Single Pan Digital Balance & Chemical Balances 30 / 02 30 / 02
11 Penta Head & Deca Head Microscopes with High-End Optics & HDMI Photographic Cameras 01 / 01 02 / 01
12 Fully Automated Immuno-histo-chemistry Setup with Important Antibodies & Lymphoma Panel 01 01
(C) Hematology Lab
01 Five-part Fully Automated Cell Counter 01 04
02 Three-part Fully Automated Cell Counter 01 04
03 Coagulometer (Fully automated) 01 01
04 HPLC 01 01
05 Cytocentrifuge 01 01